15
Sep
If you have the right power systems in your office, you can rest be assured of high level safety and
Eaton 93PM UPS Sizes: 20KW, 30KW, 40KW, 50KW, 60KW, 70KW, 80KW, 90KW, 100KW, 120KW, 130KW, 140KW, 150KW, 160KW, 170KW, 180KW, 190kw AND 200kw. Also available is N+1 redundant modules
Product Snapshot | |
---|---|
Power Rating | 20-400kW |
Voltage | 480V (208 with IAC-D) |
Frequency | 50/60 Hz |
Topology | Double conversion with optional Energy Saver System (ESS) |
Efficiency | Up to 97% in double conversion 99% in Energy Saver System |
Scalability | Up to 8 internal power modules External parallel up to 8 UPSs |
Configuration | Tower |
Batteries | Internal batteries up to 50 kW; external batteries up to 400 kW |
POWER MODULES | |
---|---|
Power Offering (kW) |
50, 50+1, 100, 100+1, 150, 150+1, 200** (Derates available in 10 kW increments) |
GENERAL CHARACTERISTICS | |
Efficiency in Energy Saver System (ESS) | 99% |
Efficiency in double-conversion mode | Up to 97% |
Parallel Capability | 8 distributed |
INPUT CHARACTERISTICS | |
Voltage | 480V (208V with IAC-D) |
Voltage range | +10% / -15% |
Frequency range | 50/60 Hz |
Power factor | >.99 |
Input current distortion | <3% @ 100% load capacity |
OUTPUT | |
Voltage | 480V (208V with IAC-D) |
Regulation | ±1% steady state |
Voltage THD |
<1% (100% linear load); <5% (non-linear load) |
Load power factor range | .8 leading to .8 lagging without de-rating |
BATTERY | |
Battery voltage | 432V |
Charging method | ABM® or float technology |
CERTIFICATION | |
Safety | UL1778, cUL |
EMC | FCC Part 15 subpart B class A |
Surge | IEC 61000-4-5 |
OPTIONAL ACCESORIES | |
External slim maintenance bypass Integrated distribution cabinet (with input and output transformer options) Integrated parallel tie cabinets Integrated battery cabinet (small and large) |
1. Due to continuous product improvements, program specifications are subject to change without notice.
The EATON 93PM is an ideal three-phase solution for providing a high quality power backup system for your white or gray datacenter space. Typical applications include but are not limited to:
UPS Models |
---|
Eaton 93PM UPS (20-400 kW) Specifications |
We respect your privacy and will never share your email address with anyone without your explicit permission.
Subscribe to Our Blog
Categories
Video
Changing your UPS batteries every 4 years can prevent 90% of all UPS outages.
A regular maintenance routine for your Eaton UPS system is mandatory to prolong its life and derive the best performance
The expectant life span of a battery is between 3 to 5 years, and experts recommend replacing the battery once